Sheng LiA/Prof, PhD(Unimelb)School of Civil and Resource Engineering University of Science and Technology BeijingAddr: No. 30, Xueyuanlu Street, Haidian District, Beijing, 100083, ChinaEmail: shengli@ustb.edu.cnProfessional Experience 2024 – Present Associate professorSchool of Civil and Resource Engineering University of Science and Technology Beijing, China2018 – 2021 Senior research engineerLaboratory of vibration control in electrical substationsChina Electric Power Research Institute, Beijing, China2013 – 2017 Research engineerLaboratory of geotechnical engineeringChina Electric Power Research Institute, Beijing, ChinaTertiary Education History PhD, Infrastructural Engineering The University of Melbourne, Australia Master by research, Bridge and Tunnel Engineering Beijing Jiaotong University, China Bachelor of Engineering, Civil Engineering Nanchang University, China Research Field Earthquake engineering and disaster mitigation Safety of urban infrastructures Seismic isolation of bridges and industry facilities; seismic performance of modular structures Rocking structures Seismic monitoring system Journal articlesLi, S., Tsang, H. H., & Lam, N. Seismic Performance of Fully Modular High-rise Buildings with Superelastic Tendon Restrained Rocking, Journal of Structural Engineering. 2024. DOI: 10.1061/JSENDH/STENG-12979Li, S.; Hu, Y.; Lu, Z.; Song, B.; Huang, G. Seismic Isolation of Fragile Pole-Type Structures by Rocking with Base Restraints. Buildings 2024, 14, 1176Li, S., Tsang, H. H., & Lam, N. Seismic internal force in rocking shear frame with superelastic tendon restraint, Earthquake Engineering & Structural Dynamics. 2023;52:2272–2293.Li S, Cheng Y, Lu Z, Lam N, Xue Y, & Wang, H. Full-Scale Testing on Seismic Performance of Surge Arrester with Retrofitted Composite Insulators. Buildings. 2022;12(10).Li, S., Tsang, H. H., & Lam, N. Seismic protection by rocking with superelastic tendon restraint. Earthquake Engineering & Structural Dynamics 2022;51:1718–37.Cui, J., Che, A., Li, S., & Cheng, Y. A maximum-entropy-based multivariate seismic vulnerability analysis method for power facilities: A case study on a ±1100-kV dry type smoothing reactor. Engineering Failure Analysis. 2022;142(106740).Cui J, Che A, Li S, Cheng Y. Evaluation method on seismic risk of substation in strong earthquake area. PLOS ONE 2021;16:1–22.Xue Y, Cheng Y, Zhu Z, Li S, Liu Z, Guo H, et al. Study on Seismic Performance of Porcelain Pillar Electrical Equipment Based on Nonlinear Dynamic Theory. Advances in Civil Engineering 2021;8816322.Cheng Y, Li S, Lu Z, Liu Z, Zhu Z. Seismic risk mitigation of cylindrical electrical equipment with a novel isolation device. Soil Dyn Earthq Eng. 2018;111:41-52.Li S, Tsang HH, Cheng Y, Lu Z. Seismic testing and modeling of cylindrical electrical equipment with GFRP composite insulators. Compos Struct. 2018;194:454-467. Li S, Tsang HH, Cheng Y, Lu Z. Considering seismic interaction effects in designing steel supporting structure for surge arrester. J Constr Steel Res. 2017;132:151-163.Li S, Tsang HH, Cheng Y, Lu Z. Effects of sheds and cemented joints on seismic modelling of cylindrical porcelain electrical equipment in substations. Earthquakes Struct. 2017;12(1(1)):55-65.Li S, Lu Z, Zhu Z, Liu Z, Cheng Y, Lu X. Dynamic properties and seismic fragility of substation composite insulators. Eng Mech. 2016;33(4):91-97. DOI: 10.6052/j.issn.1000-4750.2014.08.0712Li S, Lu Z, Qiu N, Cheng Y, Lu X, Liu Z. Study on shaking table test of 1000 kV surge arrester with metal damper device. High Volt Eng. 2015;41(5):1740-1745. DOI: 10.13336/j.1003-6520.hve.2015.05.044Li S, Cheng Y, Lu Z, Zhu Z, Qiu N, Cheng G. Seismic fragility analysis of connected post insulators. Electr Power. 2016;49(4):61-66. DOI: 10.11930/j.issn.1004-9649.2016.04.061.06Cheng Y, Liu Z, Li S, Lu Z, Liu H, Min Z. Study on the seismic test of electrical equipments interconnection circuit with flexible bus. Earthquake Engineering and Engineering Dynamics 2018;38:168–75.Cheng Y, Zhu Z, Lu Z, Li S, Qiu N, Zhong M. Earthquake Simulation Shaking Table Test on Coupling System of 500 kV Surge Arrester and Instrument Transformer Interconnected With Rigid Tube Bus. Power System Technology 2016;40:3945–50.Zhu Z, Lu Z, Cheng Y, Lu X, Li S, Huang B. A Reading of the Technical Code for Seismic Design of Interconnected High Voltage Electrical Equipment. Smart Grid 2015;3:978–82.Cheng Y, Liu Z, Lu Z, Zhu Z, Li S, Liu H. Experimental Study on Seismic Performance and Structural Characteristics of ±800 kV Composite Post Insulators. Electric Power 2017;50:89–96.Zhong M, Cheng Y, Lu Z, Zhu Z, Liu Z, Li S. Study on nonlinear characteristics on seismic response of UHV electrical equipment. Building Structure 2017;47:364–9.Liu H, Cheng Y, Lu Z, Zhu Z, Li S. Study on the Flexural Behavior of ±1100kV Composite Post Insulators. Insulators and Surge Arresters 2018;5:207–14.Wang F, Zhong T, Qiao X, Li S. Two shear theories application in numerical simulation of joint pseudo-static test. Earthquake Engineering and Engineering Dynamics 2014;34:593–6.Li S, Zhong T, Zhang C. Study on Seismic Performance of LRB Based on Probabilistic Seismic Demand Analysis. Journal of Vibration and Shock 2013;32:48–53. Research ProjectsA selected list of research projects is as follows:(1) Project title: Research on seismic safety protection technology for electrical substations (converter stations), 2018-2021 Role: Sub-Investigator(2) Project title: Seismic Safety Risk Monitoring and Assessment of Electric Grid Facilities, 2020-2020Role: Principal Investigator(3) Project title: Design and deployment of seismic monitoring system in electrical substations, 2019-2020Role: Principal Investigator(4) Project title: Seismic Performance Assessment of Large Substation, 2019-2020Role: Principal Investigator(5) Project title: Vibration testing of 1000 kV transformers and reactors in full assembly during movement, 2019-2020Role: Principal Investigator(6) Project title: Research on seismic technology and seismic monitoring application in UHV substations in high-intensity zones, 2018-2019Role: Principal Investigator Technical Codes/GuidelinesHave participated and authored in the following technical codes development as a convenor or working group member:(1) Standard of the electrical industry in China, DL/T 1960-2018, Technical code for seismic test of substation electrical equipment(2) Standard of State Grid Corporation of China, Q/GDW 11594-2016 Seismic performance testing method for composite post insulator(3) Standard of State Grid Corporation of China, Q/GDW Guidelines for seismic safety risk assessment of electrical substations, in press(4) Standard of State Grid Corporation of China, Q/GDW 11391-2015 Technical code for seismic design of high voltage pillar type electrical equipment(5) Standard of State Grid Corporation of China, Q/GDW 11267-2014 Technical Code for Seismic Design of Interconnected High Voltage Electrical Equipment(6) International Council on Large Electric Systems, WG B3-64 Guidelines on Optimising Seismic Design of Substations for Power Resiliency, in developmentPatentsA selected list of patents is as follows:(1) Chinese patent, A method for calibrating the seismic capacity parameters of composite insulators in substations, ZL 201510725097.7(2) Chinese patent, A comprehensive testing system for mechanical properties of composite insulators, ZL 201410773339.5(3) Chinese patent, Lead alloy shear-type vibration damper for cylindrical electrical equipment, ZL 201610696323.8(4) Chinese patent, A vibration isolation system with displacement restraining function and its installation method, ZL 201510772593.8(5) Chinese patent, An earthquake monitoring station for electrical substations, CN202220376617.3(6) Chinese patent, A wireless sensor network for disaster mitigation of electrical substation, CN202221607616.1Awards or HonoursA selected list of received awards or honours is as follows: 2021, Melbourne Research Scholarship, from the University of Melbourne 2021, Science and Technology Progress Award, from China Electric Power Construction Association 2016, Science and Technology Progress Award, from the Government of Xinjiang Province in China 2015, Excellent Technical Service Award, from China Electric Power Research Institute
Lisheng
+
Profile
Current position:
Home
/ Personal Profile